Time of Flight Diffraction (ToFD)

You are here

Time of Flight Diffraction (ToFD)

Time of Flight Diffraction (ToFD) is ideal for weld procedure development. ToFD setup is very fast and can be done without building a calibration standard when a quick clean/dirty weld determination is needed. ToFD is very helpful when multiple weld bevels need to be evaluated or other parameters are changing during procedure development. STANLEY Inspection also uses ToFD as an excellent supplement to full-coverage pulse-echo weld inspection.